A dealership network carries very different kinds of traffic: customer phones on guest Wi-Fi, showroom kiosks, F&I workstations with credit applications open, service-lane tablets, parts counter computers, cameras, phones and the connection to the dealer management system (DMS). On a flat network, all of those devices can reach one another. This article explains how to divide a dealership network into zones and which parts of the FTC Safeguards Rule bear on that work. It is general information, not legal advice; confirm with your counsel how the rule applies to your dealership.
What a flat network means
A flat network is one where every device shares the same segment and nothing between them filters traffic. It is common in buildings where the network grew one switch and one access point at a time. The practical effect is that a compromised device anywhere in the building, whether a showroom PC that opened a malicious attachment or an outdated camera, can try to reach the F&I office, the file server and every other computer. Segmentation divides the network into zones and puts firewall rules between them, so each zone can reach only what it needs.
Where the Safeguards Rule comes in
The Safeguards Rule’s list of required safeguards in 16 CFR 314.4 does not use the word “segmentation”, but several provisions bear directly on network design. For dealerships the rule covers, section 314.4(c) includes:
- Access controls, “including technical and, as appropriate, physical controls,” to authenticate and permit access only to authorized users and to limit users to the customer information they need for their duties (314.4(c)(1)). Network zones are one of the technical controls that keep a showroom or service device from reaching F&I data.
- Identifying and managing the data, personnel, devices, systems and facilities that the business relies on (314.4(c)(2)). You cannot segment a network without first knowing what is on it.
- Encryption of customer information in transit over external networks and at rest, or approved compensating controls where encryption is infeasible (314.4(c)(3)).
- Policies, procedures and controls to monitor and log the activity of authorized users and detect unauthorized access to customer information (314.4(c)(8)).
The rule also requires a broader written program, including a Qualified Individual, a written risk assessment and a written incident response plan; section 314.6 exempts institutions with customer information on fewer than five thousand consumers from some of those elements, including the written risk assessment and incident response plan. This article covers only the network side.
A zone plan for a dealership
Every store is different, but most dealership networks can be divided along these lines:
| Zone | Typical devices | What it should reach |
|---|---|---|
| F&I and business office | F&I workstations, accounting PCs, office printers | The DMS, lender and credit portals, file server, internet |
| Sales and showroom | Sales desks, showroom kiosks, sales tablets | The DMS and CRM, internet; not the F&I file shares |
| Service lane | Advisor tablets, technician laptops, diagnostic equipment | The DMS, manufacturer portals, internet |
| Parts | Counter PCs, label printers, scanners | The DMS, supplier portals, internet |
| Payment devices | Card terminals | Only the payment processor; ask your processor how it wants them connected |
| Cameras and building systems | Cameras, recorders, door controllers | Their own management system only |
| Guest Wi-Fi | Customer phones and laptops | The internet only, with devices isolated from one another |
| Management | Switches, firewalls, access points | Reachable only by administrators |
Between zones, the default should be to block traffic, then allow specific connections the business needs. Write those rules down so they can be reviewed when systems change.
Wireless and wiring
Each Wi-Fi network should map to one zone. Guest Wi-Fi should never share a network with dealership devices, even temporarily, and staff devices should connect to a staff network that requires individual sign-in rather than a shared password where the equipment supports it. Wired ports in public areas, such as the showroom or waiting room, should be disabled or assigned to the guest zone. Our wireless networking page explains how we design Wi-Fi around these boundaries.
Encrypting traffic that leaves the building
Customer information travels between the dealership and the DMS host, lenders, credit bureaus, manufacturer portals and, for multi-rooftop groups, other stores. Check that each of those connections is encrypted. Web portals should use HTTPS, links between rooftops should use a site-to-site VPN, and older integrations that send files by unencrypted FTP or email should be replaced or documented as exceptions for the Qualified Individual to review.
Logging what crosses the boundaries
Segmentation also makes monitoring more useful. When the firewall sits between zones, it can log blocked and allowed connections, which shows when a device tries to reach something it should not. Keep those logs long enough to investigate an incident, and make sure someone reviews alerts. A managed firewall handles both the rules and the logging.
What to do next
Draw the current network: list every device type, where it connects, and whether anything filters traffic between the showroom, service lane, parts and F&I. Fill in the zone table for your store and mark the connections that cross zones today. Titan Tech is not an auditor or assessor, but if you want an outside view of how your network is laid out, you can request a Blind Spot Scan.